2026/5/21 Installed new power supplies to Radar1

2026/5/21 Radar 2 brough up to 601, Radar1, Radar2, RCP8, and RVP8 all connected locally. Difficulty connecting to RVP8.

2026/5/27 problem connecting to RVP8 determined to be a boot issue, connected a monitor and keyboard to RVP8, and determined it was having difficulty connecting to hard drive. Reseated hard drive ribbon cable, boot sequence now works as intended. When keyboard is connected, requires key input at power on and pressing esc to boot before beginning sequence.

2026/5/27 mod voltage Fuse F3 10asb blown. New fuse ordered. Temporarily fitted a 15asb fuse, loud mechanical sound, 15asb fuse removed.

2026/5/27 door latch bolt replaced, door switch still not always signaling closed, waiting fixes issue.