atmos:3d-paws:und00200
Table of Contents
3D-PAWS - UND 00200
Summary
- Serial Number - UND00200
- NCAR CHORDS ID - 65
- UND CHORDS ID -
- Location - Clifford Hall Roof (South Side Pole Outside of Clifford Hall
- Status - Inactive
Teamviewer Info
- ID: 313 583 415
- Pass Word: Standard Airborne Team Password
Instruments
Anemometer | Inactive |
Wind Vane | Inactive |
Radiation Shield | Inactive |
Light Sensor | Inactive |
Rain Gauge | Inactive |
Links
Issue: Upgrade from Jessie to Stretch
Instrument log
- 12/16/2020: Anemometer is unbalanced
- 12/18/2020: Reset Power
- 01/08/2020: Anemometer re balanced. UV lighter sensor had been blown over but has been realigned
- 03/15/2021: Station power cycled
- 05/09/2021: Raspberry Pi suffered water damage, Pi was removed from housing box but frame still needs to be removed from roof. Pi needs replacement. Wind Vane will be updated to digital version and program will be updated to latest version before redeployment
- 02/23/2022: Undergoing repairs, Wind Vane is updated to digital version and currently troubleshooting before final re-assembly and re-deployment.
- 10/23/2022: Removed from roof. Inconstant and poor data is being recorded. currently inspecting for loose wires and replacing as needed. So far only the radiation shield wiring harness has been replaced with shielded variant. instruments appear functional.
atmos/3d-paws/und00200.txt · Last modified: 2022/10/03 20:04 by 127.0.0.1