5 Port Gust Probe on Nose of the Citation Aircraft
Description: Flow Angle Sensor
Manafacturer: Rosemount Aerospace
Model Number: 858AJ
Measurement: Differential pressure transducers measure the alpha (attach), beta (sideslip), and pitot pressure (indiated air speed).
Notes: Additional information is avaiable in the GustProbe_858FlowAngleSensor.pdf file
Instrument Log
October, 2012
Rewired the transducer box and new grounding to eliminate noise. Removed nichrome wire from pitot tube and installed heat tape over entire length to prevent freezing.
September 26, 20112
Removed the transducer box from the nose so David can test it in the CH423 lab (for noise level) with the other A/D board.
October 1, 2010
Performed leak test on the nose bloom lines. Found leak in the Pitot Static line, were heating wire enter the line inside compartment and another leak in tip where grounding line connects.
September 30, 2010
Blow water out of the pressure transducer lines. Only water in the Pitot Static line, other four lines had no water.
October 5, 2010
Performed a pressure check on the 6 lines and all looked good except the pitot would not hold a vacuum. Found leak and sealed, all looked good.
October 15, 2010
Tested the anti-ice on the gust probe to verify it's working.