| Ch | Tag | Desciption | Serial # | Range | Cal-Slope | Cal-Offset | Units | Status | Calibration Note | 
	
	
		| 0 | 100 | Spare | Not Installed | 5 volts | 1.0 | 0.0 | volts | Not Installed | default | 
	
		| 1 | 101 | Attack Angle (Validyne) | 24685 | 5 volts | 6.91 | 0.16 | volts | Installed | Calibration Feb. 11, 2010 | 
	
		| 2 | 102 | Side Slip Angle (Validyne) | 75876 | 5 volts | 6.91 | -0.4 | volts | Installed | Calibration Feb. 8, 2010 | 
	
		| 3 | 103 | Pitot Dynamic Nose (Rosemount) | F2AF7B1B | 5 volts | 17.3 | -1.44 | volts | Installed | Calibration Feb. 8, 2010 | 
	
		| 4 | 104 | Pitot Dynamic Wing | 121713 | 5 volts | 44.07 | -0.96 | volts | Installed | Calibration Feb. 1, 2010 | 
	
		| 5 | 105 | Static Pressure | Not Installed | 5 volts | 207.08 | 0.71 | volts | Installed | Calibration Jan. 29, 2010 | 
	
		| 6 | 106 | Cabin Pressure | Not Installed | 5 volts | 275.44 | -1.16 | volts | Installed | Calibration Jan. 29, 2010 | 
	
		| 7 | 107 | Temp Left Wing | 57095 | 5 volts | 28.207588 | -70.088114 | volts | Installed | Calibration Nov. 9, 2009 | 
	
		| 8 | 108 | Temp Right Fuselage | A30131 | 5 volts | 23.045123 | -64.852771 | volts | Installed | Calibration Nov. 17, 2009 | 
	
		| 9 | 109 | Chilled Mirror | Not Installed | 10 volts | 20.0 | -70.0 | volts | Installed | From Instrument Configuration | 
	
		| 10 | 110 | King Slave | Not Installed | 10 volts | 1.0 | 0.0 | volts | Installed | From m300 hot_wire_moniter | 
	
		| 11 | 111 | King Signal | Not Installed | 10 volts | 10.0 | 0.0 | volts | Installed | From m300 hot_wire_signal | 
	
		| 12 | 112 | CPC Flow Meter | Not Installed | 5 volts | 0.3895 | 0.0107 | volts | Installed | Calibration Mar. 17, 2010 | 
	
		| 13 | 113 | De-Ice System Indicator | Not Installed | 10 volts | 1.0 | 0.0 | volts | Not Installed | Default | 
	
		| 14 | 114 | TDL High Bit | Not Installed | 10 volts | 1.0 | 0.0 | volts | Installed | Default | 
	
		| 15 | 115 | TDL Low Bit | Not Installed | 10 volts | 1.0 | 0.0 | volts | Installed | Default | 
	
		| 16 | 116 | TDL 2f Mon | Not Installed | 10 volts | 1.0 | 0.0 | volts | Installed | Default | 
	
		| 17 | 117 | TDL flow meter | Not Installed | 5 volts | 1.9733 | 0.7359 | volts | Installed | Calibration Mar. 17, 2010 | 
	
		| 18 | 118 | Inlet Pressure | Not Installed | 5 volts | 207.02 | -2.0377 | volts | Installed | Calibration April 13, 2010 | 
	
		| 19 | 119 | GustBox Static Pres. (Honeywell) | 53166 | 10 volts | 205.199 | -0.1358 | volts | Not Installed | Calibration April 20, 2010 | 
	
		| 20 | 120 | Goodrich Channel 0 | Not Installed | 10 volts | 1.0 | 0.0 | volts | Installed | Default | 
	
		| 21 | 121 | Goodrich Channel 1 | Not Installed | 10 volts | 1.0 | 0.0 | volts | Installed | Default | 
	
		| 22 | 122 |  | Not Installed |  | 1.0 | 0.0 | volts | Not Used | Default | 
	
		| 23 | 123 |  | Not Installed |  | 1.0 | 0.0 | volts | Not Used | Default | 
	
		| 24 | 124 |  | Not Installed |  | 1.0 | 0.0 | volts | Not Used | Default | 
	
		| 25 | 125 | CPC Set Pressure | Texas A&M |  | 1.0 | 0.0 | volts | Not Used | Default | 
	
		| 26 | 126 | CPC Measured Pressure | Texas A&M |  | 1.0 | 0.0 | volts | Not Used | Default | 
	
		| 27 | 127 | H2 Flow rate #2 | Texas A&M |  | 1.0 | 0.0 | volts | Not Used | Default | 
	
		| 28 | 128 | H2 flow rate #1 | Texas A&M |  | 1.0 | 0.0 | volts | Not Used | Default | 
	
		| 29 | 129 | Total Flow Rate | Texas A&M |  | 1.0 | 0.0 | volts | Not Used | Default | 
	
		| 30 | 130 | SF6 Signal | Texas A&M |  | 1.0 | 0.0 | volts | Not Used | Default | 
	
		| 31 | 131 |  | Not Installed |  | 1.0 | 0.0 | volts | Not Used | Default |