12/16/2020: Anemometer is unbalanced
12/18/2020: Reset Power
01/08/2020: Anemometer re balanced. UV lighter sensor had been blown over but has been realigned
03/15/2021: Station power cycled
05/09/2021: Raspberry Pi suffered water damage, Pi was removed from housing box but frame still needs to be removed from roof. Pi needs replacement. Wind Vane will be updated to digital version and program will be updated to latest version before redeployment
02/23/2022: Undergoing repairs, Wind Vane is updated to digital version and currently troubleshooting before final re-assembly and re-deployment.
10/23/2022: Removed from roof. Inconstant and poor data is being recorded. currently inspecting for loose wires and replacing as needed. So far only the radiation shield wiring harness has been replaced with shielded variant. instruments appear functional.