===== Vaisala HMK15 Humidity Calibrator ===== * Description: Calibration set up for Vaisala Humidity Sensors * Manufacturer: [[https://www.vaisala.com/en|Vaisala]] * Manufacturer Spec Site: [[https://www.vaisala.com/en/products/instruments-sensors-and-other-measurement-devices/instruments-industrial-measurements/hmk15|Vaisala HMK15 Humidity Calibrator]] * Model: HMK15 * Manual: [[file:///C:/Users/vosas/Downloads/HMK15-User-Guide-M210185EN-E.pdf|HMK15 User Guide]] ==== Parts ==== {{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-06-30_142944.png?400|}} {{:undefined:screenshot_2026-06-30_144243.png?400|}} * Main Board * Salt Solution Chambers (x2) * Sensor Cap Attachment (x2) * Sensor Cap Plugs (x10) * Thermometer * Measuring Cup * {{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-06-30_140049.png?200|}} * Plastic Probe/Stirring Stick * {{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-06-30_140059.png?200|}} * Adapter Rings (x3) * {{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-06-30_143016.png?300|}}{{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-06-30_143025.png?300|}} * Salts * {{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-06-30_135932.png?300|}}{{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-06-30_143008.png?300|}} * NaCl (75% RH) * K2SO4 (97% RH) * All available salts * Lithium chloride LiCl (11% RH) * Magnesium chloride MgCl2 (33% RH) * Sodium chloride NaCl (75% RH) * Potassium chloride KCl (85% RH) * Potassium sulphate K2SO4 (97% RH) * Calibration/Preparation Date Tags * {{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-06-30_140023.png?300|}} * Certificate of Calibration/Inspection * {{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-06-30_140036.png?300|}} ==== Calibration Process ==== Need: * HMK15 Humidity Calibrator * Vaisala Humidity Sensor * Deionized water Steps: - Prepare salt solutions - Take the calibrator out of the box and place it on a clean, even surface. - Remove the transit cover of the salt chamber. - Remove the chamber lid from the chamber holder and put it aside. - Press the transit cover on the chamber holder. - Pour the required amount of ion exchanged water into the salt chamber. - LiCl: 12 ml - MgCl2: 3 ml - NaCl: 10 ml - KCl: 10 ml - K2SO4: 10 ml - Sprinkle the contents of a salt package (or measure the required amount of salt 1) in small quantities into the chamber, stirring constantly. - LiCl: 15 g / 18 ml - MgCl2: 30 g / 30 ml - NaCl: 20 g / 15 ml - KCl: 30 g / 30 ml - K2SO4: 30 g / 20 ml - When measuring with the measurement cup, make sure that the cup is clean and dry. Rinse and dry the cup after every use. - When all the salt has been sprinkled into the chamber, the saturated salt solution should have a ratio of 60… 90% undissolved salt to 10…40% liquid. - Close the salt chamber with the chamber lid. - Fasten the salt chamber on the holder in the base plate and close the measurement holes with rubber plugs. - The chambers can also be used individually, without the base plate. - The rubber plugs have three steps, each of which is suitable for a certain hole diameter: the first step for the 12 mm (0.47 in), the second step for the 13.5 mm (0.53 in), and the third step for the 18.5 mm (0.73 in) hole. - Keep the holes always closed when not calibrating. - Write the preparation date on a sticker and use it to mark the chamber. If you use a ready-dosed salt package, use the sticker with the batch code. Mark all parts of the salt chamber (chamber, chamber lid, and transit cover) with stickers. This way, the lids/covers and different salts do not get mixed. {{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-08-14_135409.png?400|}} - Allow approximately 24 hours for stabilization before use so that the salt solution reaches the equilibrium humidity. - Depending on the frequency of use and the general operating conditions, the salt solutions maintain their characteristics for 6 - 12 months, after which they must be replaced. Perform a visual check every 2 - 3 months. There must be a minimum of 10 % of undissolved salt at the bottom of the chamber (max. 90 %). The salt must be clean, otherwise it must be reprepared. - Calibrate Instrument - Remove the cover from the end of the thermometer and flip it around the other way. {{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-08-14_135625.png?400|}} {{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-08-14_135604.png?400|}} - Complete the following steps twice, once for each solution. Ensure that the probe head does not get wet. - Insert the thermometer into the largest hole of the calibration cover of the solution. - Remove the cover on the probe and insert into the calibration cover. - Wait for the reading to stabilize, and record both the humidity reading and the temperature - This could take 10-30 minutes. {{:undefined:screenshot_2026-08-14_134332.png?200|}} - Repeat for the second solution. - Adjust instruments - Using the values you recorded and the following table, find the equation to adjust readings from the probe. - It will follow the form: - y = mx + b - where x = raw value - y = corrected value {{:atmos:citation:instruments:vaisalahmk15calibrator:screenshot_2026-08-14_132424.png?980|}}