atmos:citation:research:soda_proecessing_1d_and_2d_hail_2d_hvps1
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
atmos:citation:research:soda_proecessing_1d_and_2d_hail_2d_hvps1 [2024/05/19 02:49] – klinman | atmos:citation:research:soda_proecessing_1d_and_2d_hail_2d_hvps1 [2024/05/21 14:23] (current) – klinman | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | Notes for self | + | On board the T28 aircraft was a Hail Spectrometer and High Volume Particle Spectrometer (HVPS). Both probes output 2D data, and the Hail Spectrometer also output 1D data. The HVPS had an array of 256 diodes, |
- | * np.ceil or np.round | + | |
- | * for cases where 1 count, but soda does correction of * 1.1 / 5 | + | The counts generated from SODA are saved in a 14xn array where n is the number of x second intervals, where x can be specified when using the SODA gui. x is set to 5 seconds |
- | * so the 1 count would be 1 *1.1 /5 = ~.2 | + | |
- | * hail counts from disp count forward. so 241841 | + | {{: |
- | * cant say i understand | + | |
- | * what doesn' | + | {{: |
- | * what also doesnt make sense is that the concentration | + | |
- | * could i be looking at the wrong code | + | The time interval for 241846 - 241851 is shown. Note that the time intervals count up to 5 seconds |
- | * ok update to previous bullet point. just not multiplying by 1.1 seems to be the move??? | + | |
- | * i think im missing where in aarons code he actually makes the concentration | + | To calculate concentration from counts, the basic forumla |
- | * and im still confused about why the counts should be /5 but thats not the step that I see taken in the code | + | |
+ | Conc (#/m^4) = Counts / (SA * Airspeed * Binsize change) | ||
+ | |||
+ | where | ||
+ | * SA is sample area which is (probe arm length * height) | ||
+ | * Height is (number of diodes * diode size) | ||
+ | * Binsize change is the (Max_Size - Min_Size) for each channel. | ||
+ | * For channel 1 for the Hail Spectrometer, | ||
+ | |||
+ | SODA includes extra variables in it's calculations. I can not explain why SODA includes these extra factors, | ||
+ | * Counts | ||
+ | * This is the Poisson | ||
+ | * In additions to SA, Airspeed, and Binsize change, SODA also divides by " | ||
+ | * " | ||
+ | |||
+ | The new formula | ||
+ | |||
+ | Conc (#/m^4) = (Counts * corr_fac) / (SA * Airspeed * Binsize change * activetime) | ||
+ | |||
+ | where for the Hail Spectrometer, | ||
+ | * Probe arm length: 0.99 m (SODA version) | ||
+ | * Diode size: 0.009 m | ||
+ | * Diodes: 64 (SODA version) | ||
+ | * Airspeed: ~100m/s | ||
+ | * Binsize change: 0.001, 0.001, 0.001, 0.001, 0.0014, 0.0016, 0.002, 0.0026, 0.003, 0.0031, 0.0044, 0.006, 0.0079, 0.01 | ||
+ | * Corr_fac: ~1.1 | ||
+ | * activetime: | ||
+ | |||
+ | When you consider the counts being multiplied by the correction factor and divided by the active time, the 2D counts from SODA better match the 1D counts. In the image below, the 2D counts | ||
+ | |||
+ | {{: | ||
+ | |||
+ | With the counts from the first image plugged into the second formula, the resulting | ||
+ | |||
+ | {{: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | The SODA concentrations agree fairly well with the DISP concentrations. | ||
+ | |||
+ | Notes to self on information to include, mention, explore, etc, | ||
+ | | ||
+ | * Time counts forward | ||
+ | | ||
+ | * Sometimes, although I believe this is fixed in my math now, my calculated 2D concentrations are 1.1x higher. But again, I think this isn't an issue anymore. | ||
+ | * Sample volumes check out. Airspeed checks out. SODA uses one airspeed for whole time interval. Include a comparison of the numbers | ||
+ | * Include a comparison of the different probe specs used in 1D and 2D calculation | ||
+ | * | ||
+ | |||
+ | to get rid of sec from airspeed, | ||
+ |
atmos/citation/research/soda_proecessing_1d_and_2d_hail_2d_hvps1.1716086960.txt.gz · Last modified: 2024/05/19 02:49 by klinman